» DROPOUT FUSE

DROP- OUT FUSE [11 kv D.O. FUSE SET MEDIUM]

Application
The dropout (swing out) fuse is an expulsion type and its main function is to protect Transformers on rural distribution network. It is also particularly useful for inaccessible Sub-stations where indication of fusing is of advantage.

Specification

Type Expulsion type Drop out, Outdoor type.
Mounting Vertical Mounting.
Standard Specification IS 9385 / 1983.
System Voltage 12 / 24 kV, 36 kV.
Rated Current 100 / 200 Amp.
Insulation Level As per IS Standard.
Fuse Carrier S R B P / Fiber Tube.
Operation In service, the fuse carrier is latched-in.

On blowing of fuse element, the fuse carrier hangs down vertically from the bottom contact. This is advantageous locating the fault as hanging fuse carrier is noticeable from distance and this save times which otherwise would be taken in investigation.
Lift out the fuse carrier by means of the insulated operating rod, rewire the fuse element and swing it up the carrier and thus remake the circuit.

DROP – OUT FUSE [ 11 kv D.O. FUSE SET HEAVY]

Application
The dropout (swing out) fuse is an expulsion type and its main function is to protect Transformers on rural distribution network. It is also particularly useful for inaccessible Sub-stations where indication of fusing is of advantage.

Specification

Type Expulsion type Drop out, Outdoor type.
Mounting Vertical Mounting.
Standard Specification IS 9385 / 1983.
System Voltage 12 / 24 kV, 36 kV.
Rated Current 100 / 200 Amp.
Insulation Level As per IS Standard.
Fuse Carrier S R B P / Fiber Tube.
Operation In service, the fuse carrier is latched-in.

On blowing of fuse element, the fuse carrier hangs down vertically from the bottom contact. This is advantageous locating the fault as hanging fuse carrier is noticeable from distance and this save times which otherwise would be taken in investigation.
Lift out the fuse carrier by means of the insulated operating rod, rewire the fuse element and swing it up the carrier and thus remake the circuit.

DROP – OUT FUSE [ 11 kv D.O. FUSE SET BRACKET TYPE]

Application
The dropout (swing out) fuse is an expulsion type and its main function is to protect Transformers on rural distribution network. It is also particularly useful for inaccessible Sub-stations where indication of fusing is of advantage.

Specification

Type Expulsion type Drop out, Outdoor type.
Mounting Vertical Mounting.
Standard Specification IS 9385 / 1983.
System Voltage 12 / 24 kV, 36 kV.
Rated Current 100 / 200 Amp.
Insulation Level As per IS Standard.
Fuse Carrier S R B P / Fiber Tube.
Operation In service, the fuse carrier is latched-in.

On blowing of fuse element, the fuse carrier hangs down vertically from the bottom contact. This is advantageous locating the fault as hanging fuse carrier is noticeable from distance and this save times which otherwise would be taken in investigation.
Lift out the fuse carrier by means of the insulated operating rod, rewire the fuse element and swing it up the carrier and thus remake the circuit.

DROP – OUT FUSE [ 22 kv D.O. FUSE SET]

Application
The dropout (swing out) fuse is an expulsion type and its main function is to protect Transformers on rural distribution network. It is also particularly useful for inaccessible Sub-stations where indication of fusing is of advantage.

 

Specification

Type Expulsion type Drop out, Outdoor type.
Mounting Vertical Mounting.
Standard Specification IS 9385 / 1983.
System Voltage 12 / 24 kV, 36 kV.
Rated Current 100 / 200 Amp.
Insulation Level As per IS Standard.
Fuse Carrier S R B P / Fiber Tube.
Operation In service, the fuse carrier is latched-in.

On blowing of fuse element, the fuse carrier hangs down vertically from the bottom contact. This is advantageous locating the fault as hanging fuse carrier is noticeable from distance and this save times which otherwise would be taken in investigation.
Lift out the fuse carrier by means of the insulated operating rod, rewire the fuse element and swing it up the carrier and thus remake the circuit.

 

  1. Automatic voltage stabilizer/ Battery Charger
  2. IPS/UPS (True On Line, Off Line)
  3. Sub-Station Equipment’s
  4. Air Conditioner
  5. CCTV